Kobol Helios64 ============== The `default.nix` module provides the required setup for the system to work. The `recommended.nix` module adds recommended settings for the system. Status ------ ### Works - SATA hard drives - Ethernet (1gbps) - Serial through USB type-c (`ttyS2`) ### Untested - Ethernet (2.5gbps) - DP video out - UPS behaviour - `rootfs` on SATA drives ### Disabled Due to misbehaviour, `ttyS0` (`&uart0`, `serial@ff180000`) has been disabled via a kernel patch. Without this change, using, or attempting to use `ttyS0` will break serial output from `ttyS2`. Kernel ------ Only Linux 5.10 (LTS) is supported, using the patch set derived from Armbian. Requirements ------------ A *platform firmware* needs to be provided out of band for the system. The author recommends Tow-Boot, for which a [draft pull request](https://github.com/Tow-Boot/Tow-Boot/pull/54) adds support for the Helios64. Any other supported *platform firmware* should work too. > **NOTE**: at the time of writing (2021-10-10) the *platform firmware* > **must** make use of the proprietary ram training. The open source equivalent > will make the system unstable, and worse, will cause silent memory > corruption, in addition to loud memory corruption. Notes ----- ### Baud rate The serial baud rate is configured for `115200`, which is a more common default than the usual for Rockchip at `1500000`. See [the rationale for the decision](https://github.com/Tow-Boot/Tow-Boot/pull/33).